ANALISA KONDENSOR TERHADAP PEMANFAATAN PANAS WATER HAETER PADA AC CENTRAL

Risman, M (2022) ANALISA KONDENSOR TERHADAP PEMANFAATAN PANAS WATER HAETER PADA AC CENTRAL. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
ANALISA KONDENSOR TERHADAP PEMANFAATAN PANAS WATER HAETER PADA AC CENTRAL.pdf

Download (539kB)

Abstract

Kondensor merupakan komponen pendingin yang sangat penting yang berfungsi untuk memaksimalkan efisiensi pada mesin pendingin. Pada kondensor ini, terjadi pelepasan kalor secara kondensasi dan kalor sensibel. Pada umumnya menggunakan kondensor tipe permukaan (surface condenser), tipe kondensor ini merupakan jenis shell-tube yang mana air pendingin disirkulasikan melalui tube. Kondensor biasanya menggunakan sirkulasi air pendingin dari menara pendingin (cooling tower) untuk melepaskan kalor ke atmosfir, atau once-through water dari sungai, danau atau laut. Berdasarkan latar belakang tersebut di atas, maka pertanyaan utama yang ingin dicari jawabannya pada akhir penelitian adalah : a) bagaimana pengaruh faktor ukuran tube dan diameter shell terhadap kondensor. b) bagaimana Performansi Sistem Refrigerasi (COP) sebelum dan sesudah menggunakan Water Heater. Dengan menggunakan data spesifikasi alat penukar kalor kondensor untuk tipe shell and tube didapat hasil perhitungan diameter shell, Ds = 815 mm dan jumlah tube, Nt = 245 buah. Penurunan COP dari 4,17 untuk AC tanpa dilengkapi dengan water heater menjadi 3,29 untuk AC dilengkapi dengan water heater, disebabkan penambahan panjang pipa, banyak pemakaian katup disertai banyaknya belokan. The condenser is a very important cooling component that functions to maximize the efficiency of the cooling machine. In this condenser, heat is released by condensation and sensible heat. In general, using a surface type condenser (surface condenser), this type of condenser is a shell-tube type in which cooling water is circulated through the tube. Condensers usually use circulating cooling water from a (cooling tower) to release heat to the atmosphere, or once-through water from a river, lake or ocean. Based on the above background, the main questions to be answered at the end of the study are: a) how is the effect of tube size and shell diameter factors on the condenser. b) how is the Performance of the Refrigeration System (COP) before and after using the Water Heater. By using the specification data for the condenser heat exchanger for shell and tube type, the calculation results for the shell diameter, Ds = 815 mm and the number of tubes, Nt = 245 pieces. The decrease in COP from 4.17 for AC without being equipped with a water heater to 3.29 for AC equipped with a water heater, due to the addition of pipe length, a lot of valve usage accompanied by many turns.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: kondensor, COP, water heater
Subjects: T Technology > TJ Mechanical engineering and machinery
Depositing User: M. Risman
Date Deposited: 30 Jun 2022 04:05
Last Modified: 30 Jun 2022 04:05
URI: http://eprints.uniska-bjm.ac.id/id/eprint/11011

Actions (login required)

View Item View Item