ANALISIS RANCANGAN BILIK STERILISASI SISTEM MIST MAKER ULTRASONIK BERBASIS SENSOR GERAK

wijaya, arif yuda (2022) ANALISIS RANCANGAN BILIK STERILISASI SISTEM MIST MAKER ULTRASONIK BERBASIS SENSOR GERAK. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
SKRIPSI ARIF YUDA WIJAYA 2 perbandingan.docx

Download (3MB)

Abstract

Abstrak Tingginya penyebaran corona virus dengan bertambahnya pasien positif corona menjadi alasan banyak masyarakat, instansi pemerintah, lembaga penelitian, dan pusat perbelanjaan membuat bilik sterilisasi, yang dapat menyemprotkan desinfektan dengan jangkauan sebaran embun cukup besar dan dirasa sangat membasahi tubuh. Pengkabutan sistem ultrasonic mengubah cairan menjadi partikel air dan kemudian menjadi kabut, Dari cairan itu masuk ke mist maker dan diubah menjadi uap air, dengan diarahkan ke box ruangan. Lebih efektif apabila di aplikasikan dengan timer dan sensor otomatis. Metode uap bisa mencapai seluruh badan rencananya dengan menggunakan Sensor gerak di depan Box, saat seseorang akan masuk dengan jarak kurang lebih 1 m sensor ini akan menghantarkan tegangan listrik kemudian sensor ini akan mentrigger pin, output pin mengaktifkan driver Relay yang menyebabkan relay pada mode normaly close sehingga listrik mengalir ke lampu sehingga lampu hidup. Rentang hidupnya lampu dikontrol oleh komponen yang di rangkai menstotable bersama. Di rangkaian saat lampu menyala, sinyal ini akan mengaktifkan mist maker atau alat pembuat uap sehingga alat pembuat uap ini akan aktif dan blower akan mentransfer uap ke dalam Bilik sterilisasii. kemudian dengan adanya variable lubang saringan dapat dihasilkan suatu semburan kabut yang stabil dan dengan percobaan waktu yang efektif untuk seorang memakai bilik sterilisasi dengan hasil waktu 8 detik dan memakai 15 lubang saringan, harapannya seorang yang memakai tidak menunggu didalam bilik terlalu lama dan mendapat sebaran kabut menyeluruh. Abstract The high spread of the corona virus with the increase in positive corona patients is the reason why many people, government agencies, research institutions, and shopping centers make sterilization booths, which can spray disinfectant with a fairly large dew distribution range and feel very wet on the body. The ultrasonic misting system converts liquid into water particles and then into mist, from the liquid it enters the mist maker and is converted into water vapor, directed to the room box. More effective when applied with automatic timers and sensors. The steam method can reach the entire body of the plan by using a motion sensor in front of the box, when someone will enter with a distance of approximately 1 m this sensor will conduct an electric voltage then this sensor will trigger the pin, the output pin activates the Relay driver which causes the relay to normally close mode so that electricity flows to the lamp so that the lamp turns on. The life span of the lamp is controlled by components that are stable together. In the circuit when the light is on, this signal will activate the mist maker or steam generator so that the steam generator will be active and the blower will transfer the steam into the sterilization chamber. Then with the variable filter holes, a stable mist burst can be produced and with an effective time trial for someone using the sterilization chamber with a result of 8 seconds and using 15 filter holes, hopefully someone who uses it does not wait in the chamber too long and gets a complete mist distribution.

Item Type: Thesis (Diploma)
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Faculty of Engineering, Science and Mathematics > School of Electronics and Computer Science
Depositing User: Arif Yuda Wijaya
Date Deposited: 06 Aug 2022 02:12
Last Modified: 06 Aug 2022 02:12
URI: http://eprints.uniska-bjm.ac.id/id/eprint/11160

Actions (login required)

View Item View Item