ANALISIS PERBANDINGAN REFRIGERANT MC-22 DENGAN REFRIGERANT R-22 PADA SISTEM AIR CONDITIONING (AC) ½ PK

Maulana, Fajar (2021) ANALISIS PERBANDINGAN REFRIGERANT MC-22 DENGAN REFRIGERANT R-22 PADA SISTEM AIR CONDITIONING (AC) ½ PK. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
Artikel Fajar Maulana.pdf

Download (321kB)

Abstract

Penggunaan refrigeran MC-22 adalah jenis refrigeran yang ramah lingkungan dibandingkan dengan meggunakan refrigeran konvesional seperti contohnya R-22 yang selama ini dipakai dan sudah harus dibatasi penggunaanya sehingga pada akhirnya penggunaan refrigeran MC-22 ini menjadi alternatif pengganti refrigeran R-22. Pengunaan refrigeran MC-22 pada AC split tentunya akan berbeda dibandingkan dengan R-22 sehingga akan meningkatkan temperatur pada suction line dan temperatur disharge line lebih rendah, pada kondisi lain kerja kompresi semakin kecil akibatnya efisiensi atau COP (Coefficient Of Performance) akan meningkat dan berdampak pada pemakaian energi yang digunakan pada mesin pengkondisian udara tersebut. Penelitian ini bertujuan agar dapat mengetahui pengaruh perbedaan refrigerant terhadap Coefficient Of Performance (COP) dan Efesiensi dari AC Split. Dari hasil penelitian maka di dapat nilai COP dari MC-22 = 12,69 lebih tinggi dari R-22 = 10,79. Dan untuk hasil nilai Efesiensi dari MC-22 = 62,92 lebih tinggi dari R-22 = 40,8. he use of refrigerant MC-22 is a type of refrigerant that is environmentally friendly compared to using conventional refrigerants such as R-22 which has been used so far and its use must be limited so that in the end the use of MC-22 refrigerant becomes an alternative to R-22 refrigerant. The use of refrigerant MC-22 in split AC will certainly be different compared to R-22 so that it will increase the temperature on the suction line and lower the discharge line temperature, in other conditions the compression work will be smaller as a ressult the efficiency or COP (Coefficient Of Performance) will increase and have an impact on the energy consumption used in the air conditioning machine. This study aims to determine the effect of refrigerant differences on the Coefficient Of Performance (COP) and the Efficiency of Split AC. From the research ressults, the COP value of MC-22 = 12.69 is higher than R-22 = 10.79. And for the ressults, the efficiency value of MC-22 = 62.92 is higher than R-22 = 40.8

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Refrigerant, Coefficient Of Performance (COP), Efesiensi
Subjects: T Technology > TJ Mechanical engineering and machinery
Depositing User: Trisna Novia Mega Putri
Date Deposited: 24 Aug 2022 03:54
Last Modified: 24 Aug 2022 03:54
URI: http://eprints.uniska-bjm.ac.id/id/eprint/12158