EFEKTIFITAS STERILISASI PERALATAN MEDIS DENGAN METODE STEAM DAN METODE PLASMA DI TINJAU DARI PARAMETER ANGKA KUMAN (TPC) DI RUMAH SAKIT SARI MULIA BANJARMASIN TAHUN 2020

RAHMANI, HENDRA (2020) EFEKTIFITAS STERILISASI PERALATAN MEDIS DENGAN METODE STEAM DAN METODE PLASMA DI TINJAU DARI PARAMETER ANGKA KUMAN (TPC) DI RUMAH SAKIT SARI MULIA BANJARMASIN TAHUN 2020. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
Atrikel.pdf

Download (124kB)

Abstract

Rumah Sakit sebagai institusi penyedia pelayanan kesehatan berupaya untuk mencegah risiko terjadinya infeksi bagi pasien dan petugas rumah sakit. Infeksi nosokomial merupakan infeksi merupakan infeksi yang didapat selama perawatan atau pemeriksaan di rumah sakit tanpa ada tanda-tanda infeksi sebelumnya. Salah satu sumber infeksi nosokomial adalah sterilitas alat medis. Penelitian ini bertujuan untuk mengetahui perbedaan angka kuman pada peralatan medis yang telah disterilisasi dengan menggunakan metode steam dan metode plasma di Rumah Sakit Sari Mulia Banjarmasin. Jenis rancangan penelitian ini menggunakan post test design, sampel yang digunakan berjumlah 10 sampel yang diberi perlakuan pada 2 jenis metode yaitu metode steam dan plasma. Hasil penelitian yang diperoleh dari metode steam didapatkan rata-rata angka kuman 1,4 koloni/cm dan pada metode plasma didapatkan rata-rata angka kuman 0,8 koloni/cm, sehingga metode plasma lebih efektif ditinjau dari parameter angka kuman. Dalam menjamin kualitas sterilisasi perlu dilakukan pemeriksaan ataupun pengujian secara rutin peralatan medis yang telah di sterilisasi. Hospitals as health care providers work to prevent the risk of infection for patients and hospital staff. A nosocomial infection is an infection obtained during treatment or examination at the hospital with no prior signs of infection. One source of nosocomial infection is sterility of medical devices. This research aims to find out the difference in germ rates in medical equipment that has been sterilized using steam method and plasma method at Sari Mulia Hospital Banjarmasin. This type of research design uses post test design, the sample used in 10 samples that are treated in 2 types of methods namely steam and plasma method. The results of the study obtained from the steam method obtained an average germ rate of 1.4 colonies /cm and in the plasma method obtained an average germ rate of 0.8 colonies / cm, so that the plasma method is more effectively reviewed from the parameters of germ numbers. In ensuring the quality of sterilization needs to be carried out regular examination or testing of medical equipment that has been sterilized.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Infeksinosokomial, Sterilisasi, Metode Steam, Metode Plasma Nosocomial Infection, Sterilization, Steam Method, Plasma Method
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
Depositing User: Hendra Rahmani
Date Deposited: 23 Dec 2020 02:33
Last Modified: 23 Dec 2020 02:33
URI: http://eprints.uniska-bjm.ac.id/id/eprint/2912

Actions (login required)

View Item View Item