ANALISIS PENYEBAB GANGGUAN PADA RELAY WINDING TEMPERATURE GENERATOR TRANSFORMER DI PLTU PULANG PISAU

Fathoni, Muhammad (2021) ANALISIS PENYEBAB GANGGUAN PADA RELAY WINDING TEMPERATURE GENERATOR TRANSFORMER DI PLTU PULANG PISAU. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
ARTIKEL ILMIAH MUHAMMAD FATHONI.pdf

Download (8MB)

Abstract

Transformator adalah alat listrik statis yang digunakan untuk mengubah atau menyalurkan energi listrik melalui suatu gandengan magnet dengan prinsip induksi elektromagnetik yang dapat menaikkan atau menurunkan tegangan atau arus dengan frekuensi sama. Keamanan sistem tenaga listrik ditentukan oleh sistem pengaman (protection system) yang baik, benar, andal atau tepat sesuai dengan kebutuhan sistem yang ada. Setelah dilakukan analisa pada saat unit mengalami shutdown diakibatkan dengan permasalahan pada Winding Temperature Generator Transformer yang muncul alarm Generator Conk Trip. didapatkan dari trending bahwa unit trip, SOE menunjukkan main electrical switch off, dan alarm pada relay protection mech 4 berwarna merah serta juga menegaskan bahwa gangguan unit bukan dari UAT atau dari frekuensi jaringan dan menjelaskan bahwa history kejadian saat unit trip yang diambil dari SOE (Sequence of Event) pada EWS (Engineering Work Station) yaitu penyebab utama trip dari main electrical switch aktif sehingga ETS (Emergency Trip System) dari perintah switch aktif dan MSV close Saat kejadian alarm yang menyala hanya pada panel proteksi Generator Transformer pada Mech 4 yang menunjukkan Winding Super High Temperature, ada masalah pada system Winding temperature tetapi tidak ada indikasi temperature winding high. Hal ini kemungkinan terjadi pada switch yang aktif akibat short. Maka dari itu penulis melakukan penelitian dan membuat simulasi terhadap penyebab gangguan pada relay winding temperature generator transformer di PLTU Pulang Pisau agar dapat mengetahui dan menjadikan pembelajaran untuk berikutnya ketika saat unit terjadi kegagalan saat operasi yang disebabkan oleh indikasi indikasi yang terbaca pada sistem recording. Transformers are static power tools used to convert or transmit electrical energy through a magnetic trailer with the principle of electromagnetic induction that can raise or decrease voltage or current with the same frequency. The safety of electric power system is determined by a good, correct, reliable or appropriate security system according to the needs of the existing system. After the writer do the analysis when the unit was shutdown due to problems in winding temperature generator transformers that caused alarm Generator Conk Trip was on. The trending shows that the unit was trip and SOE shows that the main electrical switch off, the alarm on relay protection was on, and confirmed that the unit interference is not from UAT or from the network frequency. The SOE on EWS explained that the unit was trips was because the main electrical switch was active and caused the ETS was on anf the MSV was closed. When the alarm on the Transformer Generator protection panel on the Mech 4 was on, it showed that there were problems with the Winding temperature system but there is no indication of high winding temperature. This is likely to happen when the switch was on due to short. Therefore, the aouthors do the research on the causes of the interference in realy winding temperature generator transformers in the Power Plant in Pulang Pisau in order to understand and learn when the unit occur failure during operations cause by indications read on the recording system.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator, Relay Proteksi, Sistem Record Transformer, Relay Protection, Record System
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Depositing User: Muhammad Fathoni
Date Deposited: 15 Nov 2021 02:07
Last Modified: 15 Nov 2021 02:07