ANALISIS PELUANG EFISENSI PENGHEMATAN ENERGI LISTRIK PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA RSUD PAMBALAH BATUNG AMUNTAI

Fitriani, Fitriani (2021) ANALISIS PELUANG EFISENSI PENGHEMATAN ENERGI LISTRIK PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA RSUD PAMBALAH BATUNG AMUNTAI. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
artikel skripsi.pdf

Download (642kB)

Abstract

ANALISIS PELUANG EFISENSI PENGHEMATAN ENERGI LISTRIK PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA ASPEK PENCAHAYAAN DAN PENDINGIN UDARA PADA RSUD PAMBALAH BATUNG AMUNTAI (oleh Fitriani ; Pembimbing : Ayu Novia Lisdawati, S.Si., M.Si, Irfan, MT;2021; 32 halaman) Analisis efisiensi energi listrik memiliki tujuan memperoleh penghematan energi listrik yang dikonsumsi tanpa mempengaruhi tingkat kenyamanan pada orang yang menempati suatu bangunan/gedung. Analisis efisiensi energi di RSUD Pambalah Batung Amuntai dimana hasilnya auditor memberikan berbagai tindakan peluang hemat energi yang dapat direalisasikan untuk mencapai penggunaan energi yang efisien. Pada tahun 2020 RSUD Pambalah Batung Amuntai memiliki nilai Intensitas Konsumsi Energi (IKE) sebesar 180,822 kWh/m2/tahun atau dalam kategori sedikit boros. Sehingga diperlukan proses audit rinci yang meliputi pengukuran lux (tingkat pencahayaan) dan suhu ruangan berdasarkan ketentuan, pengukuran, dan menganalisa peluang hemat energi yang akan diberikan. Peluang hemat energi yang direkomendasikan hanya 2 sistem yaitu pencahayaan dan pendingin udara (AC). ANALYSIS OF ELECTRICITY ENERGY SAVING EFFICIENCY OPPORTUNITIES IN LIGHTING AND AIR COOLING ASPECTS IN LIGHTING AND AIR COOLING ASPECTS AT RSUD PAMBALAH BATUNG AMUNTAI (by Fitriani ; Supervisor : Ayu Novia Lisdawati irfan; 32 pages,) Analysis of electrical energy efficiency has the aim of obtaining savings in electrical energy consumed without affecting the level of comfort for humans who occupy a building. Energy efficiency analysis at Pambalah Batung Amuntai Hospital where the results of the auditor provide various energy saving opportunities that can be realized to achieve efficient energy use. In 2020 Pambalah Batung Amuntai Hospital has an Energy Consumption Intensity (IKE) value of 180,822 kWh/m2/year or in the slightly wasteful category. So that a detailed audit process is needed which includes measuring lux (light level) and room temperature based on the provisions, measurements, and analyzing the energy saving opportunities that will be provided. The recommended energy saving opportunities are only 2 systems, namely lighting and air conditioning (AC).

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Efisensi , Penghematan, Pencahayaan, Pendingin udara, Energi Listrik. Efficiency, Savings, Lighting, Air Conditioning, Electrical Energy.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Depositing User: Fitriani
Date Deposited: 19 Jan 2022 02:39
Last Modified: 19 Jan 2022 02:39
URI: http://eprints.uniska-bjm.ac.id/id/eprint/7911

Actions (login required)

View Item View Item