EVALUASI PENGARUH SUHU LBS MANUAL SAAT BEBAN PUNCAK PADA PT. PLN PERSERO ULP SATUI MENGGUNAKAN THERMOVISION

Adhitya, Venus Septa Yuan (2022) EVALUASI PENGARUH SUHU LBS MANUAL SAAT BEBAN PUNCAK PADA PT. PLN PERSERO ULP SATUI MENGGUNAKAN THERMOVISION. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
Artikel_Venus Septa Yuan Adhitya_19650083.pdf

Download (339kB)

Abstract

Sistem distribusi adalah bagian yang bersentuhan langsung dengan pelanggan, sehingga ketika terjadi gangguan pada system distribusi tersebut sangat berdampak langsung terhadap pelanggan. Gangguan dalam sistem tenaga listrik tersebut mengakibatkan kerusakan peralatan sistem energi listrik sehingga mengganggu pelayanan kepada konsumen atau pelanggan secara langsung. Pada tahun 2020 jumlah gangguan peralatan sistem tenaga listrik PT. PLN (Persero) ULP Satui menempati urutan ke 3 setelah gangguan pohon dan hewan. (Rekapan Data Penyebab Gangguan PT PLN PERSERO ULP Satui Pada setiap peralatan listrik terutama pada jaringan PLN mempunyai sifat konduktifitas listrik. Benda yang bisa menghantar listrik karena berbahan dasar logam termasuk didalamnya. Ketika peralatan listrik tersebut dialiri arus listrik dari sumber maka akan timbul panas. Setiap peralatan listrik memiliki batas panas masing masing. Pada saat peralatan mengalami panas yang berlebih dari batas toleransi maka terjadi keanehan pada peralatan tersebut. Jika terus dibiarkan dan tidak ditangani dengan baik maka peralatan tersebut akan mengalami kerusakan. Untuk melakukan pengecekan dan pemeliharaan secara berkala guna mencegah terjadinya kerusakan yang lebih lanjut adalah dengan mengamati suhu dari peralatan tersebut menggunakan alat thermovision atau Thermal Camera. Alat tersebut menggunakan sinyal inframerah yang dipancarkan oleh thermovisi sehingga akan terlihat suhu dari peralatan beserta titik sumber letak panasnya. Pelaksanaan thermovision bisa dilakukan secara berkala. Hasilnya kemudian dimasukan kedalam rumus untuk mencari ∆T. Hasil perhitungan tersebut dijadikan dasar termasuk ke dalam kondisi berapa LBS tersebut. Sehingga bisa ditentukan apakah bisa langsung dipelihara atau perlu dilakukan thermovision lanjutan. Pada LBS Manual yang saya teliti ternyata hasilnya terdapat dalam kondisi I yaitu perlu dilakukan thermovision secara berkala. Jadi bisa disimpulkan untuk peralatan LBS Manual tersebut masih dalam kondisi yang baik dan bisa dioperasikan dengan normal dan tidak menimbulkan potensi terjadinya gangguan SUTM akibat peralatan. Sehingga frekuensi gangguan akibat peralatan bisa ditekan, dan untuk menekan supaya frekuensi gangguan akibat peralatan perlu dilakukan thermovision terus menerus secara berkala terhadap peralatan yang lain. The distribution system is the part that is in direct contact with the customer, so that when a disturbance occurs in the distribution system, it has a direct impact on the customer. The disturbance in the electric power system results in damage to the electrical energy system equipment so that it interferes with direct service to consumers or customers. In 2020 the number of electrical power system equipment disturbances of PT. PLN (Persero) ULP Satui ranks 3rd after tree and animal disturbances. (Data Recap of the Cause of Disturbance in PT PLN PERSERO ULP Satui In every electrical equipment, especially on the PLN network, it has electrical conductivity properties. Objects that can conduct electricity because they are metal-based are included. When the electrical equipment is powered by an electric current from the source it will generate heat. Every electrical equipment has its own heat limit. When the equipment is experiencing excessive heat than the tolerance limit, an oddity occurs in the equipment. If left unchecked and not handled properly then the equipment will be damaged. To carry out regular checks and maintenance to prevent further damage, it is to observe the temperature of the equipment using a thermovision or Thermal Camera. The tool uses infrared signals emitted by thermovisi so that the temperature of the equipment and the point of heat source will be seen. The implementation of thermovision can be done periodically. The result is then entered into the formula to find T. The results of these calculations are used as the basis for including in what conditions the LBS is. So that it can be determined whether it can be directly maintained or further thermovision needs to be carried out. In the LBS Manual, which I researched, the results were found in condition I, which requires periodic thermovision. So it can be concluded that the LBS Manual equipment is still in good condition and can be operated normally and does not cause the potential for SUTM interference due to the equipment. So that the frequency of interference due to equipment can be suppressed, and to suppress the frequency of interference due to equipment, it is necessary to carry out continuous thermovision on other equipment on a regular basis.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Thermovision, Load Break Switch Manual Thermovision, Load Break Switch Manual
Subjects: T Technology > T Technology (General)
Depositing User: Venus Septa Yuan Adhitya
Date Deposited: 09 Feb 2022 03:53
Last Modified: 09 Feb 2022 03:53
URI: http://eprints.uniska-bjm.ac.id/id/eprint/9296

Actions (login required)

View Item View Item