ANALISIS PERBANDINGAN PERENCANAAN AC CENTRAL DAN AC SPLIT DI GEDUNG FAKULTAS TEKNIK UNIVERSITAS ISLAM KALIMANTAN MUHAMMAD ARSYAD AL-BANJARI BANJARMASIN

Istianto, Yudha Hery (2022) ANALISIS PERBANDINGAN PERENCANAAN AC CENTRAL DAN AC SPLIT DI GEDUNG FAKULTAS TEKNIK UNIVERSITAS ISLAM KALIMANTAN MUHAMMAD ARSYAD AL-BANJARI BANJARMASIN. Diploma thesis, Universitas Islam Kalimantan MAB.

[img] Text
Artikel Jurnal Yudha Hery (final pdf).pdf

Download (282kB)

Abstract

Penggunaan Air Conditioner (AC) pada bangunan semakin meningkat seiring makin membaiknya daya beli masyarakat. Peningkatan penggunaan AC juga diakibatkan berubahnya kondisi temperatur lingkungan bumi yang semakin panas sebagai efek negatif dari pemanasan global (global warming effect). Hampir 70 – 80 % energi yang ada disebuah gedung digunakan untuk sistem pengkondisi udara. Sehingga dapat diprediksikan bahwa biaya pemakaian listrik sangat tinggi, sesuai dengan kenaikan beban pendinginannya. Kebutuhan AC Split pada gedung kuliah jurusan Teknik membuat mahasiswa merasa nyaman beraktifitas didalam ruangan kelas, dosen yang memberikan pelajaran pada mahasiswa jurusan Teknik juga akan merasakan nyaman dalam ruangan. Tujuan penelitian ini yaitu melakukan perhitungan perbandingan perencanaan AC Central dan AC Split pada gedung Universitas Islam Kalimantan Muhammad Arsyad Al-Banjari Banjarmasin, didapatkan hasil yaitu disimpulkan bahwa penggunaan AC Split pada gedung Fakultas Teknik Universitas Islam Kalimantan Muhammad Arsyad Al-Banjari Banjarmasin yaitu 30 unit untuk AC Split 2 PK, 12 unit AC Split 1,5 PK dan membutuhkan 684.000 BTU untuk total dari kapasitas pendinginannya, dan 574.560 watt untuk segi penggunaan daya nya. Setelah dilakukan perbandingan, maka pada setiap lantai tersebut dapat menggunakan AC Central jenis Water Cooled Chiller dengan kapasitas total pendinginan atau BTU pada ke-5 lantai tersebut yaitu sebesar 800.000 BTU atau 80 PK, dengan daya yang digunakan yaitu 903.600 watt. The use of Air Conditioner (AC) in buildings is increasing as people's purchasing power improves. The increase in the use of air conditioners is also due to changes in the temperature conditions of the earth's environment which are getting hotter as a negative effect of global warming (global warming effect). Almost 70-80% of the energy in a building is used for air conditioning systems. So it can be predicted that the cost of electricity consumption is very high, in accordance with the increase in the cooling load. The need for Split AC in the Engineering major lecture building makes students feel comfortable doing activities in the classroom, lecturers who give lessons to Engineering students will also feel comfortable in the room. The purpose of this study is to calculate the comparison of the planning of AC Central and AC Split in the building of the Islamic University of Kalimantan Muhammad Arsyad Al-Banjari Banjarmasin, the results obtained are concluded that the use of Split AC in the building Islamic University of Borneo Muhammad Arsyad Al-Banjari Banjarmasin, the results obtained are concluded that the use of Split AC in the building of the Faculty of Engineering Muhammad Arsyad Al-Banjari Kalimantan Islamic University Banjarmasin namely 30 units for 2 PK Split AC, 12 1.5 PK Split AC units and requires 684,000 BTU for the total cooling capacity, and 574,560 watts in terms of power usage. After the comparison is made, each floor can use Central AC Water Cooled Chiller type with a total cooling capacity or BTU on the 5 floors, which is 800,000 BTU or 80 PK, with the power used is 903,600 watts.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: AC Central, AC Split, Perbandingan, Perencanaan) AC Central, AC Split, Comparison, Planning)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Depositing User: Yudha Hery Istianto Yudha
Date Deposited: 08 Aug 2022 05:09
Last Modified: 08 Aug 2022 05:10
URI: http://eprints.uniska-bjm.ac.id/id/eprint/11636