Nor, Alfian (2021) OPTIMALISASI DOSIS KOAGULAN DAN PENINGKATAN KINERJA PAC (POLY ALUMINIUM KLORIDA) DENGAN PENAMBAHAN KAUSTIK SODA DALAM PROSES PENGOLAHAN AIR BERSIH DI PDAM BANDARMASIH KOTA BANJARMASIN MENGGUNAKAN METODE JAR TEST. Diploma thesis, Universitas Islam Kalimantan MAB.
Text
ARTIKEL ALFIN NOR_.pdf Download (484kB) |
Abstract
Proses penambahan koagulan harus dilakukan secara efisien karena proses koagulasi ini merupakan proses yang menghabiskan biaya terbesar dari serangkaian proses pengolahan air yang ada di PDAM Bandarmasih. Jika dosis penambahan koagulan dilakukan secara berlebihan, akan menyebabkan biaya penggunaan bahan kimia koagulan menjadi membengkak sehingga membebani pengeluaran PDAM. Metode dalam penelitian ini yang akan digunakan yaitu dengan metode analitik dimana data dari hasil uji coba beberapa dosis koagulan Poli Aluminium Klorida (PAC) yang digunakan pada kegiatan jar test diteliti untuk dijadikan dasar dalam menentukan jumlah atau dosis koagulan Poli Aluminium Klorida (PAC) yang paling optimal. Hasil penelitian sebagai berikut :Dosis optimum koagulan PAC (Poly Aluminium Klorida) untuk pengolahan air bersih di PDAM Bandarmasih sebesar 48 mg/l dengan paramater kekeruhan hasil jar test sebesar 1,44 NTU untuk metode jar test 1 dan 0,88 NTU untuk metode jar test 2.Penambahan kaustik soda / soda ash berpengaruh terhadap peningkatan hasil uji jar test untuk tingkat kekeruhan dan efisiensi pengolahan. Dimana dengan menambahkan kaustik soda / soda ash, nilai parameter kekeruhan menjadi lebih kecil (0,88 NTU) dan nilai efisiensi pengolahan menjadi lebih besar (95%). Peningkatan hasil uji jar test disebabkan karena adanya peningkatan pH air yang akan di olah menjadi 7,3 dimana kondisi pH air tesebut masuk kedalam kondisi pH optimal kinerja koagulan PAC (Poly Aluminium Klorida) yang berada di kisaran pH 7,1 sampai dengan 7,5. The process of adding coagulants must be carried out efficiently because this coagulation process is a process that costs the most of a series of water treatment processes in Bandarmasih PDAM. If the additional dose of coagulant is done excessively, it will cause the cost of using coagulant chemicals to swell, thus burdening PDAM expenses. The method in this research that will be used is the analytical method where the data from the test results of several doses of the Poly Aluminum Chloride (PAC) coagulant used in the jar test activities are studied to be used as a basis in determining the amount or dose of the poly aluminum chloride coagulant (PAC) that is the most optimal. The results of the study were as follows: The optimum dose of PAC (Poly Aluminum Chloride) coagulant for clean water treatment in PDAM Bandarmasih was 48 mg / l with the turbidity parameter of the jar test results of 1.44 NTU for the jar test method 1 and 0.88 NTU for the jar method. test 2. Addition of caustic soda / soda ash has an effect on increasing the jar test results for turbidity levels and processing efficiency. Where by adding caustic soda / soda ash, the value of the turbidity parameter is smaller (0.88 NTU) and the value of processing efficiency is greater (95%). The increase in jar test results was due to an increase in the pH of the water which would be processed to 7.3, where the pH of the water was entered into the optimal pH condition for the performance of the PAC (Poly Aluminum Chloride) coagulant which was in the pH range of 7.1 to 7.5 .
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Peningkatan Kinerja, Metode Jar Test Performance Improvement, Jar Test Method |
Subjects: | L Education > L Education (General) |
Depositing User: | Alfian Nor |
Date Deposited: | 26 Mar 2021 01:14 |
Last Modified: | 26 Mar 2021 01:14 |
URI: | http://eprints.uniska-bjm.ac.id/id/eprint/4558 |
Actions (login required)
View Item |